1mabe SERVICE MANUAL FOR SEDNA “ESTILO” REFRIGERATORS from Mabe and G.E. PUB # 06-MAN/RE-02
10 ELECTRICAL SPECIFICATIONS Temperature Control (Level 5) ... ( )°F Defrost Control ...…...…...
11 DEFROST CIRCUIT The defrost circuit has a series of components that allows the disintegration of the frost formed during the cooling cycle: con
12 If the heater is in circuit (on) for 20 minutes in the defrost cycle, the following cycle is increased by 2 hours; if it is connected for 30 minu
13 Evaporator fan motor Condenser fan motor assembly
14For these models THERE ARE 2 DIFFERENT TYPES OF ELECTRONIC BOARD: ONE FOR THE STANDARD AND DELUXE (“X”, “Y”) MODELS, which are models with BASIC EL
15 BASIC ELECTRONIC BOARD VERSION (“X”& “Y” Models, with Knob) 3.- OPERATION CHECK. DEFROST CYCLE OPERATION. A) DISASSEMBLE THE CONTROL
16 DIRECT TEST FOR THE ELECTRONIC BOARD REGULATED VOLTAGE TEST OF THE BOARD The tests described here must be carried out with the sensor locat
17 For these models THERE ARE 2 DIFFERENT TYPES OF ELECTRONIC BOARD: ONE FOR THE STANDARD AND DELUXE (“X”, “Y”) MODELS, which are models with BASIC
18 When applying voltage to the white and black cables the board is energized and 10 seconds later it sends a signal to the compressor to s
19 THERMISTOR TEST Thermistors vary their resistance value according to the temperature they detect. For example, at room temperature they have lo
20 SPECIAL FEATURES SUPER COOLING FEATURE (QUICK COOLING) When this function is selected, the LED2 light turns on, which indicates that a signal i
21 Evaporator cover assembly Airflow system Defrost system components are: the thermostat, the thermistor and the resistance (heater) Defr
22DIAGRAM
23 LIGHT BLUE
24 THE COMPRESOR USE IN SEDNA (ESTILO) REFRIGERATOR IS: COMPRESSOR CBE121L2G DOE/FIDE FOR SEDNA 17´ Y 19´ THE SAME FORM FOR POLAR 16¨AND 18´
25 PROBLEM FAILURE SOLUTION No power in the contacts. Check contacts. 1 - The refrigerator does not cool (the compressor and the light bulb do
3mabe TABLE OF CONTENTS OVERVIEW FEATURES Alarm, vacation mode, levels, turb
4 OVERVIEW The new no-frost refrigerator line called “IMAGINATION”, with 13, 15, 17 and 18 cubic foot capacity, is made in the refrigerator facto
5FEATURES A. Temperature Control Operation The internal temperatures of the freezer and fresh food compartments can be regulated individually to ma
6 Vacation Mode Directly enabled by pressing the button (when enabled, the indicator light will turn on). It is disabled by pressing the button
7Cooling Unit System Forced Air Cooling Unit This kind of system uses fans in the freezer and the condenser area to remove the hot air from
8CAPACITOR TO THERMAL PROTECTOR CONNECTION THERMAL PROTECTOR This component (installed in the compressor body) quickly detects any abnormal increa
9mabe SAFETY Before plugging the refrigerator into the electrical outlet, please make sure that: All electrical connections are grounded and a
Commentaires sur ces manuels