Mabe ESTILO Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Non Mabe ESTILO. mabe ESTILO Service manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 25
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0
1
mabe
SERVICE MANUAL FOR SEDNA “ESTILO” REFRIGERATORS from Mabe
and G.E.
PUB # 06-MAN/RE-02
Vue de la page 0
1 2 3 4 5 6 ... 24 25

Résumé du contenu

Page 1 - PUB # 06-MAN/RE-02

1mabe SERVICE MANUAL FOR SEDNA “ESTILO” REFRIGERATORS from Mabe and G.E. PUB # 06-MAN/RE-02

Page 2

10 ELECTRICAL SPECIFICATIONS Temperature Control (Level 5) ... ( )°F Defrost Control ...…...…...

Page 3 - TABLE OF CONTENTS

11 DEFROST CIRCUIT The defrost circuit has a series of components that allows the disintegration of the frost formed during the cooling cycle: con

Page 4

12 If the heater is in circuit (on) for 20 minutes in the defrost cycle, the following cycle is increased by 2 hours; if it is connected for 30 minu

Page 5 - FEATURES

13 Evaporator fan motor Condenser fan motor assembly

Page 6

14For these models THERE ARE 2 DIFFERENT TYPES OF ELECTRONIC BOARD: ONE FOR THE STANDARD AND DELUXE (“X”, “Y”) MODELS, which are models with BASIC EL

Page 7 - Cooling Unit System

15 BASIC ELECTRONIC BOARD VERSION (“X”& “Y” Models, with Knob) 3.- OPERATION CHECK. DEFROST CYCLE OPERATION. A) DISASSEMBLE THE CONTROL

Page 8 - BIMETALLIC DISC

16 DIRECT TEST FOR THE ELECTRONIC BOARD REGULATED VOLTAGE TEST OF THE BOARD The tests described here must be carried out with the sensor locat

Page 9 - BARIUM TITANATE DISC

17 For these models THERE ARE 2 DIFFERENT TYPES OF ELECTRONIC BOARD: ONE FOR THE STANDARD AND DELUXE (“X”, “Y”) MODELS, which are models with BASIC

Page 10

18 When applying voltage to the white and black cables the board is energized and 10 seconds later it sends a signal to the compressor to s

Page 11

19 THERMISTOR TEST Thermistors vary their resistance value according to the temperature they detect. For example, at room temperature they have lo

Page 13 - Condenser fan motor assembly

20 SPECIAL FEATURES SUPER COOLING FEATURE (QUICK COOLING) When this function is selected, the LED2 light turns on, which indicates that a signal i

Page 14 - Display here

21 Evaporator cover assembly Airflow system Defrost system components are: the thermostat, the thermistor and the resistance (heater) Defr

Page 15

22DIAGRAM

Page 16

23 LIGHT BLUE

Page 17

24 THE COMPRESOR USE IN SEDNA (ESTILO) REFRIGERATOR IS: COMPRESSOR CBE121L2G DOE/FIDE FOR SEDNA 17´ Y 19´ THE SAME FORM FOR POLAR 16¨AND 18´

Page 18

25 PROBLEM FAILURE SOLUTION No power in the contacts. Check contacts. 1 - The refrigerator does not cool (the compressor and the light bulb do

Page 19

3mabe TABLE OF CONTENTS OVERVIEW FEATURES Alarm, vacation mode, levels, turb

Page 20 - SPECIAL FEATURES

4 OVERVIEW The new no-frost refrigerator line called “IMAGINATION”, with 13, 15, 17 and 18 cubic foot capacity, is made in the refrigerator facto

Page 21 - Ice factory system

5FEATURES A. Temperature Control Operation The internal temperatures of the freezer and fresh food compartments can be regulated individually to ma

Page 22 - DIAGRAM

6 Vacation Mode Directly enabled by pressing the button (when enabled, the indicator light will turn on). It is disabled by pressing the button

Page 23 - LIGHT BLUE

7Cooling Unit System Forced Air Cooling Unit This kind of system uses fans in the freezer and the condenser area to remove the hot air from

Page 24

8CAPACITOR TO THERMAL PROTECTOR CONNECTION THERMAL PROTECTOR This component (installed in the compressor body) quickly detects any abnormal increa

Page 25

9mabe SAFETY Before plugging the refrigerator into the electrical outlet, please make sure that: All electrical connections are grounded and a

Commentaires sur ces manuels

Pas de commentaire